LED Display - 1: Led display zone, indicating: POWER, FOR, REV, Frequency, Current, Revolution, etc.
- 2: Main diaplay zone, indicating: Frequency, Current, AC V, DC V, Revolution, Counter temperature, etc.
- RUN: Run key
- Stop: Stop / Reset key
- JOG: FOR / REV switch
- PRGM: Fuction key
- SHIFT: ( DISP ) Shift key
- SET: Set key ( Enter )
- UP / Down: Power value change key
|
Wiring - Notice: If your motors speed is not 24000rpm, please first restore the factory settings and change PD013 to 8, then you can set other parameters, after that can you connect the VFD to 3 phase motor.
- Wiring:
- VFDs U= Spindles U1
- VFDs V= Spindles V1
- VFDs W= Spindles W1
- Connect any 2pin terminal "R", "S" or "T" of the inverter to "110VAC".
|
Multi-Protection Functions - Including overload protection, FUSE broken-motor stops protection, over-voltage / low-voltage protection, restarted by frequency track after instantaneous stop, anti-stall during acceleration/deceleration operation, electronic circuit protection.
- And many other protection functions, such as over-heat protection, restriction of reverse running, direct start after power on, fault reset, parameter lock PID, one-drive-more, ect.
|