[3210AN]
[3210AN+TS-R+RS485]
[4210AN]
[6415AN+MT50+TS-R+RS485]
Specification:
When the charging current or power of the PV array exceeds its rated current or power, it will be charged at the rated current or power.
NOTE: When the PV modules are in series, ensure that the open-circuit voltage of the PV array does not exceed the "Max. PV open-circuit voltage" rating. Otherwise the controller may be damaged. (VOC Dont exceed 92V!)
Lead-acid battery: Sealed (default) /AGM /Gel / Flooded / User (9~17V/12V; 18~34V/ 24V)
Lithium battery: LiFePO4 (4S/12V; 8S/24V), Li (NiCoMn)O2 (3S/12V; 6S/24V), User (9~34V)
Battery type selection: lead-acid (Gel, Sealed, Flooded) and Lithium, voltage parameters can be set on the controller
(For the BCV, FCV, LVD, and LVR, users can modify them on the local controller when the battery type is "USE.")
How to program for Lithium Battery?
QA
30A MPPT Controller | 30A MPPT Controller | 40A MPPT Controller | 30A DC TO DC MPPT Controller | 40A MPPT Controller | 50A MPPT Controller | |
---|---|---|---|---|---|---|
Max Rated Input Power | 12V@390W | 24V@520W | 12V@390W | 24V@520W | 12V@520W | 24V@1040W | 12V@450W | 24V@900W | 12V@520W | 24V@1040W | 625-2500W @12V-48V |
Max,PV Open Circuit Voltage | 100V/92V At 25℃ temp | 100V/92V At 25℃ temp | 100V/92V At 25℃ temp | 60V | 100V/92V At 25℃ temp | 150V/ 138V At 25℃ temp |
Grounding | Negative | Negative | Negative | Negative | Negative | Negative |
Battery Type | Sealed/Gel/Flooded/User and Lithium | Sealed/Gel/Flooded/User and Lithium | Sealed/Gel/Flooded/User and Lithium | Sealed/Gel / Flooded and User | Sealed/Gel / Flooded and User | Sealed/Gel / Flooded and User |
Supports charging single/dual batteries | Single battery | Single battery | Single battery | Dual battery | Single battery | Single battery |
Support external DC power supply? | No | No | No | ✓ | No | No |
Can it charge two different types of batteries simultaneously? | NO | NO | NO | ✓ | NO | NO |