When high level trigger is selected:
- Function 1: Power-on delayed pull-in: after a delay of T1 time from power-on, the relay pulls in, and a high-level pulse signal is given to the X interface at any time, this function resets and restarts operation;
- Function 2: Power-on delay disconnection: The relay is closed when the power is turned on, and the relay is disconnected after being closed for T1 time. A high-level pulse signal is given to the X1 interface at any time, this function resets and restarts operation;
- Function 3: Timed pull-in and then disconnection: the relay is disconnected when power is turned on, and the relay pulls in after the disconnection time T1 arrives; the relay is disconnected after the pull-in time T2 arrives, and a high-level pulse signal is given to the X interface at any time. Function reset and restart operation;
- Function 4: Regularly disconnect and then pull in: the relay pulls in when the power is turned on, the relay is disconnected after the pull-in time T1 arrives; the relay pulls in after the turn-off time T2 arrives, and a high-level pulse signal is given to the X interface at any time. Function reset and restart operation;
- Function 5: Infinite loop mode 1: The relay is disconnected when the power is turned on, and the relay is closed after the disconnection time T1 arrives; the relay is disconnected after the pull-in time T2 arrives, and then repeats the above state; give the X interface a high level at any time Pulse signal, this function resets and restarts operation;
- Function 6: Infinite loop mode 2: When the power is turned on, the relay will be closed immediately, and the relay will be disconnected after the pull-in time T1 arrives; the relay will be closed after the turn-off time T2 arrives, and then repeat the above state, and give the X interface a high voltage at any time Flat pulse signal, this function resets and restarts operation;
- Function 7: Limited cycle mode 1: The relay is disconnected when the power is turned on, and the relay is closed when the disconnection time T1 is reached; the relay is disconnected after the disconnection time T2 is reached, and then repeats more than NX actions, the number of cycles NX is 1-9999 Adjustable between times, give a high-level pulse signal to the X interface at any time, this function resets and restarts operation;
- Function 8: Limited cycle mode 2: When the power is on, the relay is closed, and the relay is disconnected after the closing time T1 is reached; the relay is closed after the opening time T2 is reached, and then repeats the action more than NX times, and the number of cycles NX is 1-9999 Adjustable between times, give a high-level pulse signal to the X interface at any time, this function resets and restarts operation;
- Function 9: Self-locking relay mode: Give a high-level pulse signal to the X interface of the relay, the relay is closed, and then a high-level pulse signal is turned off.
- Function 10: Level trigger relay mode (including delay disconnect function): When the power is turned on, the relay is disconnected, and a high level signal is given to the X interface. The relay will be closed immediately. After the X port signal disappears, the relay will still be closed. After the pull-in time T1 is reached, the relay is disconnected. Note: In this function, if T1 is set to 0 seconds, it becomes: X port has a high level signal relay to pull in, and there is no signal, it will be disconnected immediately.