Feature(may vary by option.)

●Upgraded Leak Detector: Upgraded circuit, low-consumption, compact size, easy to hold and carry.
●Fast Response: With auto calibration, it warms up in 6s and responds in 3s when leakage detected and flashes leakage level indicator light.
●Adjustable Sensitivity: 7 Grade sensitivity with maximum sensitivity of 0.11oz/yr., suitable for all kinds of leak detections.
●Replaceable Battery: 2AA Batteries needed ( not included in the package ) to power on and equip with a tri-color indicator light to display battery level.
●Safe and Reliable: Meets EN14624 and SAE-1627 industrial standards, and responds to R11, R22, R134A, R404a, R410A and all halogenated refrigerants including HFCs, CFCs, HCFCs and blends. 24/7 US Technician Support via Email and Phone.

[HLD-200 Plus]




[HLD-100 Plus]





Description

Refrigerant Leak DetectorRefrigerant Leak Detector

Elitech HLD-200+ Refrigerant Gas Halogen Leak Detector Checker for HCFCs HFCs

The HLD-200 is one of the most reliable negative corona halogen refrigerant leak detectors for HVAC at present. We integrate all our experience and customer feedback into this product, in the hope that it could provide our customers with better performance and reliability.

  • The sensitive elements adopt the advanced and reliable corona refrigerant sensor which has great sensitivity and excellent repeatability;
  • The test program is controlled by the artificial intelligent microcomputer, with reasonable work procedure, easy and convenient to operate, complete functions and multiple self-adaptive capabilities;
  • Dual-color LED indicator lights, with visual and clear display;
  • Smart and portable design is convenient for your mobile operation.
  • When there is excessive refrigerant in the leaking gas, this unit will automatically audio alarmed to effectively test the refrigerant leak.

halogen refrigerant leak detectorhalogen refrigerant leak detector

Technical Features

Refrigerant Leak DetectorRefrigerant Leak Detector

Refrigerant Leak DetectorRefrigerant Leak Detector

Refrigerant Leak DetectorRefrigerant Leak Detector

Flexible Probe

  • Around 12-inch flexible probe
  • Allows detection in difficult and hard-to-reach areas.
  • One extra sensor included in the package

2AA Batteries

  • Power supply: 2AA Batteries (not included)
  • Tri-color indicator light helps you check the battery level and change the battery in time.

Green-meet requirement for normal work.

Orange-low battery working state.

Red-battery needs to be replaced asap.

Industrial Standard

Our leak detector meets the industrial standard to help user get more safe and reliable product.

  • EN14624 standard
  • SAE-1627 standard

Product Details

11
Package Included
  • 1 X HLD-200 Leak Detector
  • 1 X User Manual
  • 1 X Extra Sensor Tip
  • 1 X Protective Case
Technical Parameter

Sensor type: negative corona sensor

Ultimate sensitivity: 0.11oz/yr

Warm-Up Time: 5s

Operating Environment: Temperature: 0℃~52℃

Humidity: <95% RH (non-condensing)

Power supply: two AA alkaline batteries (not included)

Sensor tip life under continuous operation: more than 50 hours in normal detecting status

Size: 6.9 x 2.2 x 1.3 in.

Probe length: 12 in.

wjl-6000 refrigerant leak detector 1 1 1 1 1
WJL-6000 CPU-1G HLD-100+ HLD-200 LD-200 ILD-200
Sensor Type Corona Corona Corona Corona Heated Diode Advanced
Battery Required 4 AAA 2 C 2 C 2 AA Li-1800mA/h Li-3000mA/h
Sensor Life ≥ 24 hours ≥ 24 hours ≥ 24 hours ≥ 24 hours ≥ 500 hours ≥ 10 years
Probe Length 7.87 inch 13.98 inch 13.98 inch 12.01 inch 14.37 inch 14.37 inch
Sensing Tip 1 3 2 2 1 1
Protective case - - -