Feature

●【Feature】: 5500W Pure Sine Wave Inverter 48V DC to 220V-230V AC, built in 100A Mppt charge controlle, is a new all-in-one hybrid solar charge inverter, Max 5500W 450V(Voc) Input , Starting voltage>150V. Fit for 48V Lead-Acid(AGM/FLD/Lithium/USER) and Lithium battery. Support Utility/Generator/Solar Charge.
●【LCD Setting】: Configurable input voltage range for home appliances and personal computers via LCD setting. Its comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current,AC/solar charger priority, and acceptable input voltage based on different applications.
●【Protection Function】: Overload/ Over temperature/ short circuit protection. Smart battery charger design for optimized battery performance. Can work no battery.Generate power from PV directly to supply load, even without battery.PV to AC efficiency is much higher.please know if the inverter does not connect battery, the PV voltage must be over 200VDC .
●【Four Charging Modes】 i.e. Only Solar, Mains Priority, Solar Priority and Mains & Solar hybrid charging; and two output modes are available, i.e. Inverter and Mains, to meet different application requirements.
●【Scope of Application】: This inverter can power all kinds of appliances in home or office environment, including motor-type appliances such as tube light, fan, refrigerator and air conditioner.Notice:inverter is only suitable for Single-phase 230V AC outputsystem and not suitable for 110V phase separation and parallel system! ! !

[5.5KW-48V-M100A (With MPPT Charger)]





Description

Hybrid InverterHybrid Inverter

Y&H Off Grid MPPT Solar Inverter is a new all-in-one hybrid solar charge inverter, which integrates solar energy storage &means charging energy storage and AC sine wave output

It can be accessed to a variety of household appliances and office loads, power tools, industrial equipment, and electronic audio and video equipment, including refrigerators, lamps, televisions, fans, air conditioning and other AC loads

  • Advanced MPPT technology with an efficiency of 99.9%, output of pure sine wave. Output power factor 1.0
  • Designed with a LCD screen and 3 LED indicators for dynamic display of system data and operating status.
  • vailable in 4 charging modes: Only Solar, Mains Priority, Solar Priority and Mains & Solar hybrid charging.
  • Inverter running without battery.please know if the inverter does not connect battery, the PV voltage must be over 200VDC .
  • High PV input voltage range(120-500VDC) Recommended starting voltage greater than 150V
  • Overload/ Over temperature/ short circuit protection
  • Intelligent variable speed fan to efficiently dissipate heat and extend system life.
  • Smart battery charge design to optimize battery life

inverter chargerinverter charger

4 working modes+3 load output working modes

Battery Four Charging Mode:

  • CSO: Solar energy will charge battery as priority. Utility will charge battery only when solar energy is not available.
  • CUB: Utility will charge battery as priority. Solar energy will charge battery only when utility power is not available.
  • SNU (Default): Solar energy and utility will charge battery at the same time.
  • OSO: Solar energy will be the only charging source even if utility is available.

Three Load Working Mode:

  • SOL: Solar energy provides power to the loads as priority, then Battery, then Utility AC power.
  • UTI(Default): Utility will provide power to the loads as priority, then Solar and Battery power.
  • SBU: Battery power load first, then Utility.

CAUTION! Before connecting to AC input power source, please install a separate AC breaker between inverter and AC input power source.This will ensure the inverter can be securely disconnected during maintenance and fully protected from over current of AC input. The recommended spec of AC breaker is 32A for3.5KW and 50A for 5.5KW.

Hybrid Solar InverterHybrid Solar Inverter

Line Mode Specifications

  • Input Voltage Waveform:Sinusoidal (utility or generator)
  • Nominal Input Voltage:230Vac
  • Low Loss Voltage:170Vac±7V (UPS);90Vact7V (Appliances)
  • Low Loss Return Voltage:180Vact7V (UPS);100Vac+7V (Appliances)
  • High Loss Voltage:280Vact7V
  • High Loss Return Voltage:270Vact7V
  • Max AC Input Voltage:300Vac
  • Nominal Input Frequency:50Hz/ 60Hz (Auto detection)
  • Low Loss Frequency"40±1Hz
  • Low Loss Return Frequency:42±1Hz
  • High Loss Frequency:65±1Hz
  • High Loss Return Frequency:63±1Hz
  • Output Short Circuit Protection:Circuit Breaker
  • Efficiency (Line Mode)>95% ( Rated R load, battery full charged )
  • Transfer Time:10ms typical (UPS);20ms typical (Appliances)

pure sine wave inverterpure sine wave inverter

Inverter Mode Specifications:

  • Rated Output Power:5.5KW
  • Output Voltage Wave:Pure Sine Wave
  • Output Voltage Regulation:230Vac±5%
  • Output Frequency:50Hz
  • Peak Efficiency:93%
  • Overload Protection:5s@≥150% load;10s@110%~150% load
  • Surge Capacity:2* rated power for 5 seconds
  • Nominal DC Input Voltage:48V
  • Cold Start Voltage:46.0V
  • No Load Power Consumption:<35W

Solar Hybrid InverterSolar Hybrid Inverter

Utility Charging Mode

  • Charging Algorithm:3-Step
  • AC Charging Current (Max)60Amp (230Vac)
  • Bulk Charging Voltage:Flooded Battery 58.4V
  • Bulk Charging Voltage:AGM/Gel Battery 56.4V
  • Floating Charging Voltage:54Vdc

PV (Solar) Charging

Max.PV open circuit voltage 500V(Recommended not to exceed 450V)
PV operating voltage range 120-450V
Starting voltage. ≥150V
Max Charging Current (AC charger plus solar charger) 80Amp
Maximum solar panel power 5500W
MPPT voltage 150-400V
PV charging current range 0-100A
AC cable Wire size 10 AWG
AC cable Torque Value 1.2 Nm
Battery Connection Wire size 2 AWG
PV Connection Wire size 12 AWG
AC Circuit breaker selection 50A
Hybrid Solar InverterHybrid Solar Inverter

Warning:

  • SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY !!!
  • CAUTION --To reduce risk of injury, charge only AGM/FLD/Lithium/USER batteries. Other types of batteries may burst, causing personal injury and damage.
  • For optimum operation of this inverter/charger, please follow required spec to select appropriate cable size. It’s very important to correctly operate this inverter/charger.
  • This off grid solar inverter all-in-one does not support parallel operation, and does not support phase separation!(Single phase 240V AC /A Hot Leg, NOT Support 110V !!! )
  • Note: Inverter cannot output energy to utility. This is solar off-grid system.
  • Note: Inverter power rating must be 3-7 times the inductive load power. For example, the air conditioner is 700W. 700*3=2100W. It is recommended that you purchase a minimum of 2400W-3000W. to give the inverter enough buffer.