●About CG:CG ammeter shunt is made of high quality brass and Manganin, is Sanded to make more shiny , sealing treatment to be used for a long time.
●Parameter:500A 50mV DC shunt;Voltage drop:50mV;Accuracy:+/- 0.25%;Operating Temperature:-40℃ to +60℃;Material:Copper+Manganin;relative humidity:less than or equal to 95% (35℃).
●Temperature Rise:20ppm,When the change of temperature tends to be stable,if rated current is below 50%, the temperature will be not higher than 80℃,if rated current is above 50%, the temperature will be not higher than 120℃.
●Over-load ability:rated current 120%, 2 hours.It is not recommended that the practical used current over the 80% of rated current for a long time.
●Package Content:1*500A/50mV dc shunt.

[500A 50mV]




[500A 75mV]




[50A 50mV]




[100A 100mV]





Description

shunt 500A 50mVshunt 500A 50mV
SSR-80DASSR-80DA
Shunt 500A 50mVShunt 500A 50mV

品牌徽标品牌徽标

Since the company was established in 1992. XIQI has been dedicated to the manufacture and development of industrial automated instruments more than 25 years.XIQI Electric Co., Ltd. is a professional enterprise of Industrial Automation include the Switch, Relay, Thermostat, Power Meter, Timer, Pneumatic, Contactor, Brekaer, Sensor with high quality.Our procucts have gotten the certificates of European CE. ISO9001. RoHS and IATF16949.

DC Shunt 500A 50mV

DC shunt is used to measure DC current and is made according to the principle of generating voltage at both ends of the resistor when DC current flows through it. The shunt is widely used to expand the range of measuring current of the instrument, and can be used for communication system, electronic machine, power supply of automation control and other circuits for current limiting and equal flow sampling detection.

Features:

Product Name DC Shunt
Model FL-15
Safety Standards IEC 61010-1:1990
Accuracy Grade 0.25 Class
Ambient Temperature -40~+60℃
Relative Humidity ≤95%(35℃)
Mechanical Force Resistance Can withstand acceleration of 70m/s2 and shock frequency of 8~120 times per minute for 6 hours of transportation shock
Heat Under Load Temperature stability tends to change,does not exceed 120℃
Overload Performance Rated current 120%,2 hours
Voltage Drop 50mV
computercomputer

Suggestion

1.The cable or copper row in the primary circuit should be tightened with the main connector of the shunt .

2.The secondary voltage at the sampling point of the shunt is connected to the DC ammeter.

3.Actual use current (long time) is recommended to not exceed 80% of the rated current.

500A 75mV 100A 100MV 50A 50MV 50MV
500A 75mV 100A 100mV 50A 50mV