Feature

●? Good Design : This is a great circuit breaker used to protect an electrical circuit from damage caused by excess current resulting from an overload or short circuit
●? Good Choice : Fast Closing to ensure reliable operation of the load and prolong the life of electrical circuit breakers
●? Circuit Protection Function : It is easy and reliable to use, which supports short circuit protection, overload protection
●? Features : It can be mounted conveniently on DIN rail, DIN rail is not included
●? Application : Widely used for solar panels grid system, wind and solar hybrid system and many other DC systems

[32A]




[16A]





Description

Specifications:

Model: C65H-DC 2P
Standard: IEC60947-2/GB14048.2
Poles: 2P
Rated Current: 16A/32A/63A(Optional)
Rated Voltage: DC250V
Breaking capacity: Icu=10kA
Impulse-withstand Voltage (Uimp): 5kV
Current Limiting Class: 3
Interrupter ways: vacuum circuit breaker
Mechanical Life: 20,000 times (IEC 60947-2/GB14048.2)
Electrical Life: 10,000 times (IEC 60947-2/GB14048.2)
Impulse withstand voltage: 5kV
Operating Temperature: -25℃~+70℃
Storage Temperature: -40℃~+85℃
Heat & Humidity Resistance: 55℃, 95%RH
Size: 8.2 x 3.6 x 7cm / 3.22 x 1.41 x 2.75"
Circuit BreakerCircuit Breaker

Application:

  • Solar panel off grid system
  • Solar panel on grid system
  • Wind and solar hybrid system
  • Any other DC system

Circuit BreakerCircuit Breaker

Function:

  • Short circuit protection
  • Overload protection
  • Control
  • Isolation

Circuit BreakerCircuit Breaker

Good Choice

Fast closing: to ensure reliable operation of the load and prolong the life of electrical circuit breakers

Mechanical life: 20.000 times (IEC 60947-2/GB14048.2)

Electrical life: 10,000 times (IEC 60947-2/GB14048.2)

Environment: Work ambient temperature: -25~ +70

Storage ambient temperature: -40~ +85

Resistance to hot and humid : Temperature 55, the relative humidity 95%

Dimensions :82×36×70

Anti-vibration(IEC 60068 2.6)

In the x, y, z of 5 g(g=9.81m/s⊃2;) three directions, the displacement amplitude of ±15 mm in the 9-150

Circuit BreakerCircuit Breaker

Connection

Tunnel type terminal blocks

Terminal connection area: 1~32A, the wires used in 25 2 and below

40~63A, the wires used in 35 2 and below

Circuit BreakerCircuit Breaker

Installation:

Modular structure, can be easily installed on the guide rail DIN standard

Bistable locking clip, the installation more convenient

Current Level(A):1~25/ 32~63

Screw: M5/M6.5

Rated torque(Nm):2.5/3.5

Ultimate torque(Nm):5.1/5.6

National standards Rated torque (Nm):2/3.5

C65H-DC breaker

B and C Type trip curve

IEC 60947-2/GB 14048.2, 10kA

Whats in the box

  • inc
  • inc
  • inc
  • inc
  • inc
  • inc
  • inc
  • inc
  • inc