[4 to 20mA Display Percentage]
[Ammeter]
Custom display:
For example, input 4-20.00mA and display 0-3000
Can be displayed according to the actual situation
For example, display frequency 50.0hz 100.0% valve opening flow pressure speed etc.
Can display ± positive and negative numbers:
The positive and negative values are displayed, and it is clear at a glance whether the wiring is correct;
Some occasions for feedback of positive and negative voltages, such as the positive and negative rotation of the motor, etc.;
Wide voltage 5-28V power supply, does not affect accuracy:
The power supply adopts multi-stage voltage stabilization, and the primary power supply can be different without affecting the display accuracy;
Setting
4-20mA display 0-40.0
F002=4.00 (The middle point is set to 4mA)
F003=0 (the middle point corresponds to display 0)
F004=400 (20mA corresponds to display 40.0, the decimal point will be set in F005)
F005=1 (the decimal point is 999.9)
4-20mA display 0-50.0
F002=4.00 (The middle point is set to 4mA)
F003=0 (the middle point corresponds to display 0)
F004=500 (20mA corresponds to 50.0, the decimal point will be set in F005)
F005=1 (the decimal point is 999.9)
4-20mA display 0-50.00
F002=4.00 (The middle point is set to 4mA)
F003=0 (the middle point corresponds to display 0)
F004=5000 (20mA corresponds to 50.00, the decimal point will be set in F005)
F005=2 (the decimal point is 99.99)
4-20mA display 0-60.0
F002=4.00 (The middle point is set to 4mA)
F003=0 (the middle point corresponds to display 0)
F004=600 (20mA corresponds to 60.0, the decimal point will be set in F005)
F005=1 (the decimal point is 999.9)
4-20mA display 0-100.0
F002=4.00 (The middle point is set to 4mA)
F003=0 (the middle point corresponds to display 0)
F004=1000 (20mA corresponds to 100)