Feature(may vary by option.)

●【High-efficient Recovery】The refrigerant recovery machine is equipped with a 110V-120V 60Hz dual-cylinder oil-less compressor, it has a more powerful recovery speed of 1HP, which can recover vapor and liquid refrigerants more quickly than the one with single cylinder.
●【Overload & Safety Protection】The refrigerant recycling machine comes with a built-in intake pressure gauge (blue) and a discharge pressure gauge (red), which have clear scale for easy observation at any time. When the internal pressure is above 558psi, it will shut down automatically for safe operation guarantee. Inversely, the machine will reset automatically. The unit is installed with an overload protector, if popping, the breaker switch will reposition after 5 minutes.
●【Self-purge Function】The refrigerant recovery unit has a purge switch, which can help clean up the residual refrigerants in the recovery kit and avoid it from damages caused by the residual refrigerants inside. The filter drier comes with the machine can remove moisture and liquid substance in the air, the filter is replaceable.
●【Overall Structure】The refrigerant recovery machine mainly includes a 110V-120V 60Hz dual cylinder, 1HP powerful motor and oil-less compressor. The sturdy body and good-quality components ensure the long service life, and the compact design with ergonomic handle makes the machine easy to transport and carry. The big condenser and fan with upgraded cross-flow layout design ensure the superior cooling performance, shorter cycle time and faster recovery speed.
●【Wide Application】The freon recycling unit not only fits for all kinds of Category III, IV, V refrigerants, such as R12, R134a, R401C, R406A, R500, R22, R401A, R401B, R402B, R407C, R407D, R408A, R409A, R411A, R411B, R412A, R502, R509, R402A, R404A, R407A, R407B, R410A, R507, but also fits for special refrigerants, such as R1234YF and R32. The machine is widely applied in automotive, household and commercial apliances, like air conditioner, freezer, heat pump unit, etc.

[RR250]




[RR500]





Description

RR500 refrigerant recovery machineRR500 refrigerant recovery machine
recovery machine 2recovery machine 2

1HP Dual Cylinder R1234yf Refrigerant Recovery Machine1HP Dual Cylinder Refrigerant Recovery Machine

110V-120V 60Hz, for Both Liquid and Vapor Refrigerant

FEATURES:

1. Automatic shut-off switch and reliable overload protection for safe operation

2. Multiple refrigerants matching for wide applications

3. Excellent recovery and push/pull method for high-efficient performance

4. Superior self-purge technology for longer service life

5. Durable oil-less compressor and compact design for easy carrying

Specifications

  • Power: 110V-120V, 60Hz (Dual cylinder)
  • Motor: 1HP, 1750RPM
  • Maximal current draw: 10A
  • Compressor: double-cylinder, oil-less, air-cooled, piston
  • High pressure shut-off: 38.5bar / 3850kPa (558psi)
  • Operating temperature: 0℃~40℃ / 32℉~104℉
  • Dimension: 400mm*250mm*360mm
  • Weight: 18KG

Recovery Machine Features

Oil free compressor 3-1Oil free compressor 3-1

accurate pressure gauge 3-2accurate pressure gauge 3-2

air-cooled condensor3-3air-cooled condensor3-3

Oil-free Compressor

There is no lubricating oil to pollute recovered

refrigerants with the oil-free compressor, so

you can recover most refrigerants by one freon

recycling unit, just replacing the filter drier.

Accurate Pressure Gauge

The low pressure gauge shows the input

pressure of the refrigerant recovery machine,

the high pressure gauge shows the output

pressure of the freon recycling unit.

Air-cooled Condenser

The recovery machine is installed with

a large condenser and a fan, which can

ensure the maximum cooling performance,

short cycle time and fast recovery speed.

recovery and self-purge functionsrecovery and self-purge functions

RECOVERY & SELF-PURGE METHODS

· Recovery method is for recycling liquid and vapor refrigerant with slow and fast modes.

· Self-purge method is for checking if there is refrigerant left or remained in the machine to avoid expanding or damaging the components.

push pull methodspush pull methods

LIQUID PUSH & PULL METHOD

· If the liquid refrigerant recovery is more than 10kg, it is recommended to use the push / pull method for faster process.

Freon Recycling Unit RFreon Recycling Unit R

WARNING!!!

1. Read all safety instructions carefully before use.

2. Only qualified technicians could operate this recovery unit.

3. Always wear safety goggles and protective gloves during the work. Avoid gas or liquid refrigerant.

4. Do not overfill the recovery tank. A scale is needed to avoid overfilling the recovery tank. The tank is full at 80% capacity.

5. The inlet pressure must not exceed 26bar.

6. This equipment should be used in locations with mechanical ventilation or the equipment should be located at least 50cm above the floor.

7. Do not use this equipment in the vicinity of spilled or open containers of gasoline.

8. If needed, use a 3-wire extension cord 12AWG minimum and shorter than 7.5m, with reliable grounding.

applications of refrigerant recovery unit Lapplications of refrigerant recovery unit L

WIDE APPLICATIONS

· The freon recycling unit fits for all kinds of Category III, IV, V refrigerants, such as R12, R134a, R401C, R406A, R500, R22, R401A, R401B, R402B, R407C, R407D, R408A, R409A, R411A, R411B, R412A, R502, R509, R402A, R404A, R407A, R407B, R410A, R507, as well as special refrigerants, such as R1234yf, R32.

· The machine is widely applied in automotive, household and commercial apliances, like air conditioner, freezer, heat pump unit, etc. But please note it is not allowed for explosive, flammable or corrosive refrigerants.

Product information