Feature

●Use Accuracy: The balance is equipped with 5g weights, 10g weights, 20g weights and 50g weights, as well as 5g running weights. The measurement accuracy is 0.1g and the measurement range is 0.1-110g.
●When in Use: put the object to be loaded on the left side of the balance, add weights to the right one by one or adjust the scale of the rider. After the left and right balances, remove the weights. The number marked on the weight plus the rider indicator is the measured object Actual weight.
●Quality Commitment: All products are brand new, if you have any questions, welcome to consult, and our customer service will answer you at any time.
●Before use: Before using the balance, make sure it is placed on a horizontal table and cannot be tilted; make sure that there is no liquid and powder in the trays at both ends of the balance; Rider needs to be reset to 0; adjust the balance nut so that the balance pointer points to the middle.


Description

100/500 gram mechanical scale weights for school physics experiment accessories tool for laboratory supplies

1217190034911-11217190034911-1
YTYT

High calibration accuracy, reliable and accurate data, accurate weight weight and stored in the weight box to avoid oxidation.


The tray is made of plastic material with strong fall protection, which can avoid the left and right imbalance caused by accidental damage.

11

1217190034911-21217190034911-2

1217190034911-31217190034911-3


Specification:


Item Type: Balance Scale


Set Type: 500g set/100g set (optional)



Package list:


500 g set: 1 x scale, 2 x tray, 1 x tweezers, 1 x 10 g weight, 2 x 20 g weight


1 x 50 g weight, 2 x 100 g weight, 1 x 200 g weight


100 g set: 1 x scale, 2 x tray, 1 x tweezers, 1 x 50 g weight, 2 x 20 g weight


1 x 5 g weight



Note:


Usage and maintenance methods:


1. When using the scale, you should place it on the flat workbench.


2. Move the cursor to the point “0” on the left end of the ruler: the pointer should be aligned with the center line of the header to achieve balance. Otherwise, the balance nut on the lever should be turned to adjust the balance.


3. After adjusting the scale, place the object to be weighed in the left disk and add the weight from large to small in the right disk. Try to place the object and the weight in the Center of the weighing plate when rising or falling to the minimum. If the weight is not yet balanced, the moving code can be balanced. The mass of the object is equal to the sum of the mass of the weight and the mass of the travel code.


4. After weighing is complete, the travel code must be placed back on the scale 0 and the weight must be returned to the weight box.