Feature

●Range: 50 to 650°C | Accuracy: ±0.6°C | Bath Stability: ±0.05°C | Stabilization Time: 20 Min. | Heating Time: 30 to 32 Min. (50 to 650°C) | Resolution: 0.1°C | Units: °C / °F Switchable | Display: Graphical with LED Backlight | Power Supply: 230V AC ± 5% / 50Hz,1.2 KW for 650DBC
●Transmitter Supply: 24V DC ± 10% (Loop Powered) |Block Diameter: 25.4 mm | Block Depth: 120 mm | Insertion Tube Depth: 110 mm | Temperature Setting: Digital Display through feather touch keypad | Display Stability: ±0.2°C | Radial uniformity Fixed Steps for: ±0.3°C with similar probes | Switch Test: Continuity check with OPEN / CLOSE indication
●Measuring Parameters: mA, mV, Volts, Ohms, RTD3 (Pt 100)3 | mA Range: 0 to 25 mA; Resolution: 0.001 mA; Accuracy: ±0.025% of Reading + 10 µA | mV Range: 0 to 1000.0 mV; Resolution: 0.01 mV; Accuracy: ±0.025% of Reading + 0.25 mV | Volts Range: 0 to 10.000 V; Resolution: 0.001 V; Accuracy: ±0.025% of Reading + 3 mV | Ohms Range: 0 to 400 Ohms; Resolution: 0.01 Ohms; Accuracy: ±0.025% of Reading + 0.1 Ohm | RTD3 Range: -200 to 8500 C; Resolution: 0.10 C; Accuracy: ±0.025% of Reading + 0.30 C
●Thermocouple Types: T, J, K, N, R, S | Thermocouple Range( T,J,K,R,S): -200 to 400°C; Resolution: 0.1°C; Accuracy: ±0.025 % of Reading + 1°C |Thermocouple Range(R,S): 300 to 1760°C; Resolution: 1°C; Accuracy: ±0.025 % of Reading + 1°C
●Supply Scope: 1 Unit of DBC-02 Dry Block Calibrator, Power Cable, 1 Unit of Test Lead (2 Wire), Insertion Tube: Dual Hole - 1 x 1/4” + 1 x 12.5 mm, Dual Hole - 1 x 1/4” + 1 x 8.2 mm, 1 Unit of Insertion Tool, 2no.s of 6A Spare Fuses, Instruction Manual and Factory Calibration Certificate | Applications: Calibration Labs, Pharmaceutical Divisions, Thermal Plants, Metallurgical Plants
●Dry block calibrator Temperature calibrator Rtd thermocouple calibrator Tabletop temperature calibrator Liquid bath calibrator Thermocouple simulator Dry block calibrator for calibration Labs Temperature calibrator for Pharmaceutical Divisions Temperature Calibrator for Thermal Plants Temperature Calibrator for metallurgical Plants High temperature probe calibrator Temperature calibrator 650Degree Celsius Dry block calibrator 650 Degree Celsius


Description

Ace AI-DBC Dry Block Temperature Calibrator is used while it’s in vertical position. And before any maintenance activity waits for the instrument to cool to ambient temperature. This Thermocouple Calibrator will work at ambient Temperature in such places as any Transit case or packing system. Ace Dry Block Temperature Calibrator is flammable to liquids