1. How Pymeter control Temperature?
Temperature controller is actual Heating/Cooling controller, thus MUST SET ON-Temp to turn ON Heating/Cooling, and MUST SET OFF-Temp to turn OFF Heating/Cooling.
Heating starts at LOW Temp [ON-Temp(1tN)], stops at HIGH Temp [OFF-Temp(1tF)], thus for heating MUST SET 1tN LESS than 1tF;
In heating mode, 1tN is the minimum temp you allow, 1tF is the maximum temp you allow.
Cooling starts at HIGH Temp [ON-Temp(1tN)], stops at LOW Temp [OFF-Temp(1tF)], thus for cooling MUST SET 1tN GREATER than 1tF.
In cooling mode, 1tN is the maximum temp you allow, 1tF is the minimum temp you allow.
2. How Pymeter control Humidity?
Humidification starts at LOW Humidity [ON-Humidity(2hn)], stops at HIGH Humidity [OFF-Humidity(2hF)], thus for humidification MUST SET 2hn LESS than 2hF;
In humidification mode, 2hn is the minimum humidity you allow, 2hF is the maximum humidity you allow.
Dehumidification starts at HIGH Humidity [ON-Humidity(2hn)], stops at LOW Humidity [OFF-Humidity(2hF)], thus for dehumidification MUST SET 2hn GREATER than 2hF.
In dehumidification mode, 2hn is the maximum humidity you allow, 2hF is the minimum humidity you allow.