[3 & 8 NPT Auto Drain]
[1 & 2 NPT Auto Drain]
|
|
|
---|---|---|
Gas in and out1. Clean the ports and accessories before installation, which can effectively prevent dust from entering the air channel. 2. Pay attention to whether the port and thread size match, and the gas inlet and outlet are marked with "IN" and "OUT". |
DialProof pressure:1.5Mpa(15.3kgf/cm²) Max.working pressure:1.0Mpa(10.2kgf/cm²) |
Dominate1.pull up the rotayr button to operate. 2.Clockwise rotation increases the pressure. 3.Rotate counterclockwise,the pressure decreases. 4.Atfer adjustment,press the rotary button to lock it. |
|
|
|
---|---|---|
DrainageWhen there is no pressure, it will drain automatically. When there is pressure, the drainage function will be temporarily closed lf the water level exceeds the upper limit,drain water in time to prevent poor dehumidification |
Oil AdjustmentRotate the needle valve in the "+" direction to speed up oil suction. When you rotate in the "-" direction, it will slow down or stop oil suction. |
Oil cupTurn clockwise to add oil, and the added oil shall not exceed 80% of the oil cup. After refueling, please tighten it. |
Air Regulator | Air Filter/Regulator | Air Filter | Air Pressure Regulator | Compressed Air Filter Regulator | |
---|---|---|---|---|---|
Port Size | 1/4" NPT | 3/8" NPT | 1/2" NPT | 3/8" NPT | 1/2" NPT |
Temperature Range | 41-140 °F | 41-140 °F | 41-140 °F | 41-140 °F | 41-140 °F |
Max Inlet Pressure | 145 psi | 145 psi | 145 psi | 145 psi | 145 psi |
Regulator Pressure Range | 0-145 psi | 0-145 psi | 0-145 psi | 0-145 psi | 0-145 psi |
Filter Rating | 5 Micron | 5 Micron | 5 Micron | 5 Micron | 5 Micron |
Drain | Semi-Auto | Semi-Auto | Semi-Auto | Semi-Auto | Semi-Auto |
Bowl Material | Polycarbonate | Polycarbonate w/ guard | Polycarbonate w/ guard | Polycarbonate w/ guard | Polycarbonate w/ guard |