Feature

●【ALUMINUM ALLOY MATERIAL】Shell is made of casting aluminum alloy, with plastic powder coating surface, resistant to . Automatic drainer is extremely reliable in operation, no electricity needed, no noise, no loss of compressed air.
●【MAIN FUNCTION】When the drainage buoyancy is less than the weight of the float plus the compressed air pressure, the drain outlet is closed; when the buoyancy increases, it will open to discharge the condensate. This kind of compressed air condensate automatic drainer has a large drain and is not easy to be blocked.
●【FLOATING BALL DRAIN VALVE】Model: HAD20B; Port size: inlet = outlet = 1/2BSP; maximum pressure: 20bar; maximum temperature: 100; maximum capacity: 400L/H; weight: about 602g.
●【UPGRADE AUTO DRAIN】This type of compressed air condensate auto drain is obviously different from the traditional mechanical auto drain, which belongs to continuous droplet discharge. This is a fairly stable drain with excellent performance and a low failure rate.
●【PRACTICAL TOOL】This compressed air condensate automatic drainer is significantly different from traditional mechanical automatic drainer, which is belong to continuous drops drain.


Description

Description:

This compressed air condensate automatic drainer is a mechanical automatic drainer which has casting aluminum alloy shell and inside float ball drainage system.Drainer outlet is closed when drainage buoyancy is smaller than floating ball weight plus compressed air pressure; and it will open when buoyancy increases, in order to drain condensed liquid.


Specifications:

Model: HAD20B

Port Size: Inlet=Outlet=1/2BSP

Max. Pressure: 20bar

Max. Temperature: 100℃

Max. Capacity: 400L/H

Weight: 602g(approx.)


Instruction:

Before installing this drainer, please use compressed air to remove impurities in the piping till it is completely clean.

Install this automatic drainer beneath the drainage device of equipment, otherwise condensate will be filled and affect drainage.
Maintenance
Inspect the drainer once a week.
Operation method: open manual drainer valve to drain water till compressed air in equipment enter the drainer, after a few seconds then closed valve.If drained water is more than 0.5 liters, there is a blockage and drainer need to be cleaned completely.
Internal parts should be taken out and cleaned each year.When cleaning, you can use soap water or dish-washing liquid to clean, do not use solvents, so as not to damage the rubber fittings.


Package Includes:

1 x Drain Valve

1 x Pipe Fitting