Feature

●❤❤(1)The stormer viscometer is used for the determination of paint and other KU indicating the viscosity of the coating. The instrument can display the KU value of the measured sample viscosity or the load value associated with the KU value (unit: G).
●❤❤(2)The Stormer Viscosimeter should be placed on a strong and smooth surface away from strong airflow, strong magnetic field, strong electric field and strong electric pulse interference.
●❤❤(3)The Stormer viscosity testing equipment measurement range: 40.2 ~ 141.0KU (KU value), 27cP-5250cP,32 ~ 1099g (load value);measurement accuracy: 2.0% of full range;repeatability: the full range of 2.0%;
●❤❤(4)There are precise measuring parts in the Stormer Viscosity Measurement cabinet.this Stormer Viscometer is a special instrument. Please do not open the instrument shell by itself, so as not to affect the accuracy of instrument measurement.When the instruments are temporarily unused, the lifting handle of the instrument should be kept on the high position limit unit, and it should not be placed in a lower position, otherwise the phenomenon of inflexibility may be produced.
●❤❤(5)Digital display can be read directly from the display have been tested KU value


Description

❤❤The stormer viscometer can display simultaneously: KU, cP, gram, display temperature, measuring time five units❤❤
Stormer viscometer specification
❤❤The stormer viscometer is used for the determination of paint and other KU indicating the viscosity of the coating. The instrument can display the KU value of the measured sample viscosity or the load value associated with the KU value (unit: G).
❤❤The instrument is controlled by a computer. The blade of a stirred blade (also called a rotor) is driven by a constant speed motor at a speed of 200r/min. The resistance moment of the impeller in the measured sample is converted by a computer to the KU value. unit (KU) is a logarithmic function of the load required to produce 200r/min speed, which is generally used to represent the speed of the 200r/min. It is used for the viscosity of the brush and roll. The operator only needs to enter the stirred blade into the measured depth and read the KU value of the sample or the relative load value directly from the instrument. The operator is simple and convenient to operate. The rotor is not needed to change the rotor in the whole measurement range (the rotor is the main part of the connection sensor, the improper installation will affect the measurement accuracy). This instrument is in accordance with the ASTM-D562 and GB/T9269-2009 standards.

Technical Specifications
❤❤Measurement range: 40.2 ~ 141.0KU (KU value), 27cP-5250cP; 32 ~ 1099g (load value);
❤❤Measurement accuracy: 2.0% of full range;
❤❤Measurement repeatability: the full range of 2.0%;
❤❤The rotational speed of the mixing axis: 200r/min + 1r/min;
❤❤Container capacity: About 500ml;
❤❤Input voltage: 220V 50Hz;110V((Send According to your country’s voltage)
❤❤Power: 10W;
❤❤Size: 210mm x 180mm x 500mm;
❤❤Weight: 10kg.