Feature

●It has a 2-in-1 charging mode (battery overcharge protection) and discharging mode (battery low voltage protection). The charging mode can be used for solar charging, and the battery automatically disconnects when it reaches the set voltage. The discharging mode can be used for battery low voltage protection.
●Two low-power modes: automatic mode and manual mode. Manual mode consumes 0 power after the relay disconnects, and manual button reset is required after disconnection;
●In automatic mode, the relay enters a low-power mode after disconnecting (LED turns off after 60s without any button action, and the LED resumes display when a button is pressed again). Standby current is 5mA (18V), and it automatically restarts when the voltage is restored.
●The device has an internal flash storage module, so all settings can be restored after a power off.
●Maximum 40A current, operating voltage from 5V to 60V.Supports a 99 seconds start delay, 99 seconds disconnect delay, and a 99:59:59 hours timer disconnect timer.


Description

lvplvp

Connection Diagram of Charging Mode

lvplvp

Discharge mode connection diagram

Discharge mode connection diagramDischarge mode connection diagram

  • WARNING

  1. Please make sure that "IN+ IN- OUT+ OUT-" and the positive and negative poles of the battery cannot be reversed. Reverse connection will damage the product, battery and charger;
  2. The charging mode and discharging mode need to use the button setting to switch the mode before use. See the description below for the switching method.
  3. It is a charging/discharging controller but not a charger or voltage converter.

Circuit Schematic

lvplvp

Quick start:

1. Discharge mode (battery low voltage protection mode)

For example: the working voltage of the battery is 18V, and the low-power protection voltage of the battery is 15V. It is expected to cut off the discharge when the battery voltage is less than or equal to 15V. The settings are as follows:

a. Connect the circuit according to "Figure 4.1 Discharge mode connection diagram".

b. "SWITCH 2" switch to "M" position, press "UP" or "DOWN" when the LED displays "01" Short press "SET", then the module is set to discharge mode 1.

c. "SWITCH 2" switches to "V", press "UP" or "DOWN", when the LED displays "CL", short press "SET", then press "UP" or "DOWN" to adjust the LED display value, set The value of "CL" is 15V, then press "SET" to save the value and exit the setting, and the setting will take effect.

d. "SWITCH 2" switches to "V" position, press "UP" or "DOWN" when the LED displays "CH", short press "SET", then press "UP" or "DOWN" to adjust the LED display value, set The value of "CH" is 15.5V, then press "SET" to save the value and exit the setting, the setting will take effect.

e. Switch "SWITCH 1" as needed. If it is manual mode, you need to press S1 to start the module manually, and it is not necessary for automatic mode.

2.Charging mode

For example: the working voltage of the battery is 18V, and the full saturation voltage is 20V. When the battery voltage is less than 18V, start charging, and when the battery voltage is greater than 20V, stop charging.

a. Connect the circuit according to "Figure 4.2 Connection Diagram of Charging Mode".

b. "SWITCH 2" switch to "M" position, press "UP" or "DOWN" when the LED displays "3", short press "SET", then the module is set to charging mode 3.

c. "SWITCH 2" switches to "V", press "UP" or "DOWN", when the LED displays "CL", short press "SET", then press "UP" or "DOWN" to adjust the LED display value, set The value of "CL" is 18V, then press "SET" to save the value and exit the setting, and the setting will take effect.

d. "SWITCH 2" switches to "V" position, press "UP" or "DOWN" when the LED displays "CH", short press "SET", then press "UP" or "DOWN" to adjust the LED display value, set The value of "CH" is 20V, then press "SET" to save the value and exit the setting, and the setting will take effect.

e. Switch "SWITCH 1" as needed. If it is manual mode, you need to press S1 to start the module manually, and it is not necessary for automatic mode.

lvplvp

2-in-1 Charge/Discharge And Protection Module

Functional Overview

  • LED 60s auto off
  • Charge/Discharge time control
  • Manual mode/automatic mode switchable
  • Force start time
  • Programmable delay turn on/off
  • 40A Relay
  • Suitable for 5~60V
  • "0" standby power consumption (manual mode)

Specifications

  • Working Voltage: DC 5V-60V
  • Max Current: 40A
  • Maximum power: 1200 watts
  • Standby Current: 0 in manual mode, 5mA in automatic mode at 18V
  • Voltage accuracy: 0.1V
  • Work Temperature:-25℃~80℃
  • Work Humidity:5%~90%RH
  • Shell size: 103.6mm*51.8mm*38.8mm
lvp lvp
DC 5V-60V 40A Low Voltage Cutoff with LCD Display Low Voltage Protector Low Voltage Cutoff
Customer Reviews
4.2 out of 5 stars
47
Price $15.99
Working Voltage DC 5V-60V DC 20V-30V
Load Current 40A 20~30A
Function Charging protected mode and Discharge protected mode Over Discharge Protection
Two low-power modes Automatic and manual Manual mode
Standby current 0 or 5mA(18V) 12V
Supports on and off delay 99 seconds 60 seconds