Feature

●Powerful Magnification: Our Compound Binocular Microscope offers a broad magnification range from 40X to 2500X, providing exceptional clarity for various research applications in laboratories and educational settings.
●Siedentopf Head Design: The ergonomic Siedentopf head ensures comfortable viewing by allowing easy adjustment of the interpupillary distance, catering to individual preferences and maximizing user comfort during extended use. 360-degree rotation capability to provide a more comprehensive view and enable sharing.
●Wide-Field Eyepieces: Equipped with high-quality 10X and 25X wide-field eyepieces, this microscope enhances the field of view, promoting accurate observation and reducing eye strain for researchers and students alike. With brightness adjustment knob, brightfield, LED illumination, and 1.25 NA Abbe condenser with iris diaphragm for moving up and down, clear examination and light control. Objective conjugate distance is 195mm.
●Precision Mechanical Stage: The large surface area 125mmx115mm of the double-layered mechanical stage facilitates precise and controlled movement of specimens, allowing for accurate positioning and ease of use. The length of mechanical is 160mm. Ideal for intricate observations and detailed research. Coaxial coarse and fine focus, movable up and down condenser,comfortable handwheels, easy to control, fast and accurate focusing. Coarse tuning range is 10mm.
●Ultra-Precise Focusing: With an advanced focusing system, this microscope provides ultra-precise control, allowing researchers to capture detailed images and make fine adjustments with confidence, ensuring optimal results in their studies. We provide USB cable for power and an extra box(50pcs) of glass filters.


Description

11

Application:

Biological microscope can be used for biological, pathological and bacteriological observation, teaching and professional research, clinical experiment and routine medical examination in medical institutions, universities, secondary schools and specialized schools. It adopts advanced structures and technologies to make the instrument easy to use, safe and reliable

22
22

Operation

1. Insert the eyepiece into the eyepiece tube, and screw the objective into the nosepiece. During observation, put the specimen in the center of the stage and held with the slide holder. First, use the 10X or 4X objective to find the object, then turn to the high-magnification objective for observation, turning the fine-focusing knob until the image is clear. When using 100X oil objective, should fill a drop of cedar oil between the specimen and lens, without bubbles. After used, the lens should be cleaned with xylene immediately to avoid the solidification of the cedar oil.

2, In order to get a bright and clear image when observing, must pay attention to the adjustment of the illumination system. When using the different magnification of the objective lens, should adjust the condenser and change the aperture of the light bar, so that the aperture can adapt to the objective. Generally speaking, when the magnification of the objective lens increases, the condenser should be moved upward. The aperture light bar is designed for adjusting aperture, not the brightness.

Maintenance

1 When the microscope is finished observing or suspended, cut off the power supply to avoid the electrical components in the instrument are still in the working state. When not used for a long time, the power plug should be removed from the power socket and all transmission wires should be properly kept.

2 Clean lens: Use a blow ball or a soft brush to wipe the dust off the lens. Heavy dirt and fingerprints can be gently wiped by lens paper or soft cloth dipped in a little alcohol and ether mixture (the mixture of the two is about 20 to 30% alcohol, 70 to 80% ether).

3 Clean instrument surface: Can be wiped with a clean soft cloth; Heavy dirt can be scrubbed with a neutral cleaner.

4 Storage: if you do not use the microscope for a long time, please turn off the power supply of the instrument, fully cool the bulb, put the dust-proof cover on the microscope, and put it in the packing box. Store in a dry, ventilated, clean and acid-alkali vapor-free place to avoid mold.

44
33