Feature

●Specification: Supply voltage: DC 6-30V, Trigger : High level (3.0V-24V) (The and system dont use the same GND port), Output capacity: DC 30V/5A, AC 220V/5A, Static current: 20mA, Working current: 50mA, Working temperature: -40~85.
●Sleep Mode: 1. "C-P" Sleep mode: No operation for five minutes, the digital display automatically turns off, the program runs as usual; 2. "O-d" Normal mode: digital display turns on all the time; Press and hold the "STOP" button for two seconds to switch "C-P" and "O-d" state, the current state flashes and then return to the main interface.
●Module highlights: 1. Wide voltage power supply (6~30V) supports micro USB 5.0V power supply. 2.The interface is clear and simple, powerful, easy to understand. 3. One button emergency stop function (STOP button), with reverse polarity protection to prevent burn-out.
●How to Set Timing Range: After setting the parameter value at mode selection interface, short press "STOP" button to set the timing range; ①XXX. - timing range: 1 second to 999 seconds. ②XX.X - timing range: 0.1 seconds to 99.9 seconds. ③X. X. X. - timing range: 1 minute to 999 minutes.
●Parameter setting and saving, Different OP, CL, LOP parameters can be set. These parameters are independent of each other and saved separately. All setting parameters are automatically saved after power-off.


Description

1. Working Mode:
P1: After triggers, the relay opens for "OP" time, and then disconnect; in the "OP" time, as follows:
P1.1: is triggered again, invalid
P1.2: is triggered again, restart the timing
P1.3: Give trigger , the relay closes for "CL" time, then opens for OP" time; After finishing the timing, disconnect the relay;
P3.1: Give trigger , the relay opens for "OP" time, then closes for CL" time, then the operation cycles; if give trigger again during the cycle, the relay opens, stop timing; the cycles times ( "LOP ") can be set.
P3.2: No triggering required after power on, the relay opens for "OP" time, then closes for "CL" time, then the operation cycles; the cycles times ( "LOP ") can be set.
P-4: holding function: If there is trigger , timing is cleared, the relay remains on; when the disappears, after "OP" time, the relay is off; if another is triggered during timing, timing will be cleared.

2. Parameter Description:
"OP" - on time, "CL" - off time, "LOP" - cycle times (1-999 times, "---" means infinite loop).
These parameters are independent of each other, but are shared by each mode.
In the main interface (display 000), short press "SET" button will display "OP" ( "CL", "LOP") and the corresponding time XXX;
If the mode (such as the mode P1.1, P1.2, P1.3) only has "OP" time, short press the "SET" key to display only the "OP" and the corresponding time;
Some models (such as the mode P3.1, P3.2) have parameters "OP", "CL", "LOP", short press "SET" button will display "OP" and the corresponding time, "CL" and the corresponding time, "LOP" and the corresponding number of times;