Feature(may vary by option.)

●【WIDE APPLICATION】Voltage withstand test instruments are for general- purpose HV test operation.It can be widely used for voltage withstand test in electrician’s assistant instrument,rubber-wooden facility,voltage convector,wires,power meter,motor,power supply plug,cables and all kinds of electronic and electric products.
●【PARAMETER】Model:RK2671AM; Test Voltage (AC):0~10KV +/-5%; Test Voltage (DC):0~5KV +/-5%; Leakage Current (AC):0~2/20mA +/-5%; Leakage Current (DC):0~2/10mA +/-5%; Timing (s):0~99s; Manual control; Pmax:100VA; Input Voltage(Power):110V; Weight:40lbs
●【EASY TO USE】Digital display with remote control,each button is an independent function output.The operation is simple and convenient,and the test results are more intuitive
●【PACKAGE INCLUDED】1×Withstand voltage test equipment; 1×High voltage test bar; 1×Remote control test bar; 1×Ground wire; 1×power cord.Complete accessories, more convenient to use
●【NOTICE】Operating request:Environmental temperature 0~40℃; Relative humidity≤75%.The two test lines A and B will be delivered randomly

[5KV AC 220V]




[5KV AC 110V]




[10KV AC  & DC 110V]




[5KV AC  & DC 220V]




[10KV AC  & DC 220V]





Description

RK267 series voltage withstand test instruments are for general- purpose HV test operation. It can be widely used for voltage withstand test in electrician’s assistant instrument,rubber-wooden facility,voltage convector,wires,power meter,motor,power supply plug,cables and all kinds of electronic and electric products.Precautions before use
Read the following items carefully before operating RK267 series voltage withstand test instrument
1. Use three-hole power supply plug and insure GND connection well.
2. GND port and power supply GND port should be connected well
3. Wear insulation glove, stand on insulation mat
4. Turn the “V-ADJ” rotary switch counterclockwise to the maximum before powering on.
5. Before preset all functions, reset instrument
6. Don’t connect test port and test wire when doing test
7. Don’t connect HV output port with shield box or GND wire to avoid instrument damage.
8. Turn off power when accident take place
9. Examine and repair when Indicator or annunciator is out of function
10. Operate carefully to avoid hazard when take the remote test.
11.The instrument must be placed on the worktable of conductive materials
12.The operator can not wear clothes with metal decoration or wear metal accessories
13.When the tester is in the test conditions, the test line, the test probes, output end , and the test objects are all with high pressure, do not touch