Feature

●Measuring Parameters: Frequency, OHM, Analog Transducer, DC mA, RTD, Thermocouples, Resistance, RTD Measurement, TC Measurrement, Frequency Count, Diode Test & Continuity Test.
●Process Meter Measurements: Range: DC Voltage Measurement: Range: 4.000V, Resolution: 0.001V, Accuracy: 0.2% + 4; Range: 40.00V, Resolution: 0.01V, Accuracy: 0.2% + 4; Range: 400.0V, Resolution: 0.1V, Accuracy: 0.2% + 4; DC mV Measurement: Range: 40.00mV, Resolution: 0.01mV, Accuracy: 0.5% + 6; Range: 400.0mV, Resolution: 0.1mV, Accuracy: 0.2% + 4
●AC Voltage Measurement: Range: 400.0mV, Resolution: 0.1mV, Accuracy: 1.0% + 4; Range: 4.000V, Resolution: 0.001V, Accuracy: 0.5% + 4; Range: 40.00V, Resolution: 0.01V, Accuracy: 0.5% + 4; Range: 400.0V, Resolution: 0.1V, Accuracy: 0.5% + 4; DC Current Measurement: Range: 40.00mA, Resolution: 0.01mA, Accuracy: 0.2% + 4; Range: 400.0mA, Resolution: 0.1mA, Accuracy: 0.2% + 4
●AC Current Measurement: Range: 40.00mA, Resolution: 0.01mA, Accuracy: 0.5% + 4; Range: 400.0mA, Resolution: 0.1mA, Accuracy: 0.5% + 4; Operating Temperature: 5°C to 50°C; Operating Relative Humidity: <80% RH, Storage Temperature: -10°C to 55°C, Storage Humidity: < 90% RH
●Power Supply: 6V batteries (4*1.5V alkaline AAA batteries or 4*1.5V Ni-MH AAA batteries); Maximum Voltage: 600Vp-p (Maximum Voltage between all input jacks & earth ground), 30V DC (Maximum Voltage between all output jacks & earth ground); Accessories: A copy of user manual, a set of industrial test lead (with alligator) clips and two 63mA/250V fast-blow fuses; Safety: Compiled with IEC61010 (Safety standard issued by International Electro-technical commission.
●Multifunction calibrator Process Calibrator Industrial Process Calibrator Universal Process Calibrator Thermocouple source calibrator


Description

Multifunction calibrator, Process Calibrator, Industrial Process Calibrator, Universal Process Calibrator, Thermocouple source calibrator

BTH C9 Calibrator is a very useful tool to calibrate many types of process control instruments which accept mV, mA and RTD (resistance inputs). This is designed to give highest stability and accuracy. The calibrator has a source & measure function & can be used for lab or field calibration of process control instruments, temperature & pressure transmitters, I/P convertors, field level transmitters, flow transmitters and a host of other instruments. Features of BTH C9 Universal Process Calibrator: Source & Measure Function Back Light graphic LCD Direct Calibration possible Automatic Power on/off function DC current .001mA resolution