Feature

●Self-test in 0.5 second, boot instantly
●0.01-200Ω, Wider range
●With beeps and NOISE symbol blinking. Strong anti-interference ability.
●Maximum 50mA, Longer battery life
●With fastening screws, Secure, Reliable, Easy battery replacement.


Description

etcr970-1etcr970-1

Overview

ETCR2000A+ Clamp Earth Resistance Tester is our companys technology research and development team on technical quality of the pursuit of excellence, through continuous innovation to improve, upgrade with the old product. Its performance is mainly reflected in:

  • Breakthrough in self-test the boot a long time to waiting, start immediately into the test.
  • Breakthrough relay self-test mode, using the most advanced processing algorithms and digital integration technology.
  • Breakthrough the old product too heavy issues, more in line with characteristics of hand-held devices.
  • New design, panel operation with 6 buttons, better performance.
  • Increase sound and light alarm function, with "beep-beep-beep” alarm sound.
  • Increase the interference signal recognition indicator function, with "beep-beep-beep” indicator.
  • Measurement range: 0.01Ω-200Ω
  • Stored data 99 Units. Lower power consumption, Maximum operating current less than 50mA.

ETCR2000A+ Clamp Earth Resistance Tester is widely used in the grounding resistance measurement of the power, telecommunications, meteorology, oilfield, construction and the industrial and electrical equipment. In the measurement of a grounding system with loop, does not require breaking down the grounding down lead, and no need the auxiliary electrode. It is safe, fast and simple in use. The tester can measure ground faults which cannot be measured by traditional methods. It can be used in applications where traditional methods cannot be measured, because the ETCR series clamp grounding resistance meter measures the combined value of grounding body resistance and grounding lead resistance.

Field Application

ETCR970-4ETCR970-4

The application of machine room earth resistance measurement

  • The machine room of telecommunication system normally in the upper deck of the building. It is hard to use the meg-ohm meter to measure. However, ETCR Clamp meters are very convenient to test.

The application of substation earth resistance measurement

  • ETCR series clamp meter can use to test the situation of contact and connect of circuit. With the help of one test line, it can be used to test the connect situation of equipment in station and the grounding system.

The application of building lightning protection grounding system measurement

  • If the earth poles of the building are independent of each other, the earth resistance can be measured by clamp to testing any of the earth poles, and the earth resistance can also be measured by clamp the building roof lightning arrester.When the measured value is less than the allowable value, the earth electrode is qualified.If the measurement value of the clamp meter is larger than the allowable value, please use ingle earth point method to measurement.

From the measuring principle, ETCR series Meter can only measure the loop resistance, the single-point grounding is not measured. However, users are able to use a testing line very near to the earth electrode of the grounding system to artificially create a loop for testing. For details, please read user manuals.

ETCR2000A+ Ground Resistance Meter Technical Specifications

Function Ground resistance test, Loop resistance test
Resistance Range 0.01-200Ω
Resistance Resolution 0.001Ω
Power Supply 6VDC 4 PCS of LR6 lkaline batteries
Clamp Size 65mm×32mm
Clamp Opening Extent 32mm
Accuracy ±1%±0.01Ω
Data Storage 99 sets
Alarm Threshold Setting Range Resistance: 1-199Ω
Alarm Sound and Light “Beep-beep-beep” alarm tone, Alarm Symbol Flashing, Press AL key to turn on, turn off Alarm or set Alarm Threshold.
Interference Signal Recognitio “Beep-beep-beep” tone, NOISE symbol blinking
Working Environment -20℃~55℃ 20%rh~80%rh
Store Environment -20℃~60℃; below 90%rh
LCD Screen 4 Digits LCD display, Screen L×W: 47mm×28.5mm
Tester Weight 1160g (With batteries)
Clamp Dimension L×W×T:285mm×85mm×56mm
Protection Level Double insulation
Structural Feature Clamp CT
Shift Automatic shift
External Magnetic Field <40A/m
External Electrical Field <1V/m
Single Measurement Time 0.5 second
Resistance Measure Frequency >1KHz
Measured Current Frequency 50/60Hz Automatic
Low Battery Voltage Indicator When the battery voltage is lower than 5.3V, the low battery voltage symbol is displayed
Memory Full Indication MEM symbol blinks when all 99 sets memory is full
Over Range Indication Out of range indication “OLΩ”, "L0.01” or “OL A”
Auto Power-off 5 minutes after Boot up
Power Consumption Max 50mA either in booting up or normally working, Continuously working for 30 hours
ETCR2100系列 ETCR2100系列 ETCR2100系列 2000 2000 2000
ETCR2100A+ ETCR2100+ ETCR2100C+ ETCR2000A+ ETCR2000+ ETCR2000C+
Customer Reviews
4.3 out of 5 stars
103
4.7 out of 5 stars
33
4.5 out of 5 stars
5
4.7 out of 5 stars
7
Price $165.00 $220.00 $365.00 $198.00 $297.00 $367.00
Clamp Size Φ32mm Φ32mm Φ32mm 65mm×32mm 65mm×32mm 65mm×32mm
Resistance Range 0.010Ω~200Ω 0.010Ω~1200Ω 0.010Ω~1200Ω 0.010Ω~200Ω 0.010Ω~1200Ω 0.010Ω~1200Ω
Current Range 0.00mA~20.0A 0.00mA~20.0A
ETCR2000 ETCR2000 ETCR2000 ETCR2000X ETCR2000X ETCR2200
ETCR2000 ETCR2000A ETCR2000C ETCR2000X ETCR2000XC ETCR2200
Customer Reviews
Price $212.00 $171.00 $353.00 $212.00 $216.00 $607.52
Clamp Size 55mmX32mm 55mmX32mm 55mmX32mm 55X32mm 55X32mm 65mm×32mm
Resistance Range 0.010Ω-1000Ω 0.010Ω-200Ω 0.010Ω-1000Ω 0.01-500Ω 0.01-500Ω 0.01Ω-1500Ω
Current Range 0.00mA -30.0A 0-20A 0.00mA~40.0A

Whats in the box

  • ETCR2000A+ Resistance Tester, Test Ring, Instrument Box, Instruction Manual