Feature

●Our inductive capacitance meter can be powered by mini USB cable or Φ5 DC power supply cable.also you can install 4 AA batteries(4 AA batteries is not included).
●The LC inductor capacitor tester measuring range:Capacitance 0.01pF-100mF, inductance 0.001uH-100H, frequency 500KHz/500Hz-50KHz.
●The capacitance measuring instrument provides Accuracy 1% of capacitance range 1pF~1uF, 5% of range 1uF~100mF; 1% of inductance range 1uH~1H, 5% of range 1H~100H
●The handheld LC inductor capacitor tester is based on the LC resonant principle, wide measurement range, high accuracy, small size, light weight and portable.
●This capacitance meter kit include 1 handheld LC meter,1 pair of banana plug to alligator clip test leads,1 LCR alligator clip test lead,1 mini USB cable, 1 charging cable and 1 manual.


Description

FEATURES

Measurement Range:

C -----Capacitance (0.01pF-10uF)

L -----Inductance (0.001uH-100mH)

Hi.L -----Large inductance (0.001mH-100H)

Hi.C -----Large capacitance (1uF-100mF)

Calibration:

Capacitance mode -----open circuit calibration;

Inductance mode -----short circuit calibration.

Frequency display:

Press the function button while testing, the current frequency will be displayed.

Mode “C”: measure small capacitance

Accuracy: 1pF~1uF--1%; 1uF~10uF--5%

Resolution: 0.01pF

Mode “L”: measure small inductance

Accuracy: 1uH~100mH--1%

Resolution: 0.001uH

Mode “Hi.L”: measure large inductance

Accuracy: 100mH~1H--1%; 1H~100H--5%

Resolution: 0.001mH

Mode “Hi.C”: measure large capacitance

Accuracy: 1uF~100mF--5%

Resolution: 0.01uF

Test frequency:

Mode “C”, mode “L”~500KHz

Mode “Hi.L”~500Hz ~50KHz

The measurement method of large capacitance: Charge-discharge

Working temperature: 0℃-40℃

Working humidity:≤90%RH (At 40 ℃)

NOTE:

The capacitor under test must have been completely discharged, otherwise, the meter will be damaged.

It needs more time to measure a big capacitance (over 10mF, more than 1s; 100mF, about 8s).

If the meter needs to switch the testing mode, it should be calibrated to keep measurement accuracy.

For measuring the electrolytic capacitors, the selected mode should be “Hi.C”.

Specifications:

Supply Voltage: 5V

Power Supply: Φ5 DC power supply and mini USB cable (both of them included), or 4*AA batteries (not included)

Dimensions (L x W x H): 150 x 89 x 29mm

Weight: 198g

Package includes:

1×handheld LC meter

1 pair of alligator clip test leads

1×LCR alligator clip test lead

1×mini USB cable

1×Φ5 DC power supply

1×manual