Feature

●【6 KINDS OF FUNCTIONS】The module has 6 kinds of commonly used functions to meet the needs of more applications.
●【WIDE APPLICATION】The electrical motor control board can control 2-way solenoid valve, pumps, motors, lights and other running freely.
●【TIME RANGE】The time range of the module is 0.1 seconds to 999 minutes and is adjustable any time.
●【OUTPUT POWER】The motor control board can control within 30A DC or AC load.
●【GOOD PERFORMANCE】The motor timer relay module with good performance, also is easy to install and has a long service life.


Description

Motor ControllerMotor Controller

Specification:

The two-way pump controller has 6 common functions, and the functions can be set arbitrarily to meet more application needs; it can control 2 way solenoid valves, water pumps, motors, light strips, etc.

Forward / Reverse Control BoardForward / Reverse Control Board

Key Settings Description:

Power display "----" that access to standby;

Press the first time K1, the screen shows: P-1: K2 and K3 adjustment mode

Press the second time K1, the screen shows: A001: K2 and K3 adjust the first time A, K4 adjust the decimal point (time unit)

Press the third time K1, the screen shows: B001: K2 and K3 adjust the second time B, K4 adjust the decimal point (time unit)

Press the fourth time K1, the screen shows: C001: K2 and K3 adjust the third time C, K4 adjust the decimal point (time unit)

Press the fifth K1, display "----" that entered the standby state;

For example; need to set the mode: P - 2; time: A010 B005 C006:

Indicating the second mode of operation; after the signal 1; relay 1 after 10 seconds to start off; relay 2 to give the signal after delay 5 seconds after the start 1 second automatically shut down

Motor ControllerMotor Controller

Model:YYB-5

Input voltage: DC/ AC 7V~27V

Time range: 0.1 seconds to 999 minutes

Weight: Approx.103g/3.6oz

Motor Forwards Reverse Stop GovernorMotor Forwards Reverse Stop Governor

Wiring port Description:

1. AC/DC : Input 7V~27V

2. IN1: Signal input 1 (negative trigger)

3. IN2: Signal input terminal 2 (negative trigger)

4. IN3: Signal input 3 (negative trigger)

5. NO: relay normally open interface, relay pull before the suspension, after the connection with the COM shorted

6. COM: relay common interface

7. NC: relay normally closed interface, the relay before the connection with the COM shorted, pull after the suspension

Function list:

Motor Timing Cycle ModuleMotor Timing Cycle Module

Motor Relay Delay ModuleMotor Relay Delay Module

Dual DC Motor Speed ControllerDual DC Motor Speed Controller

P - 1: to signal 1, relay 1 pulls to A time automatically stops; to signal 2, relay 2 pulls to B time automatically stops; signal 3 is emergency stop reset signal

P - 2: signal 1, relay 1 is pulled to A time automatically stop; relay 2 from the signal to start delay B time after the suction to C time automatically stop (this function time unit needs to be consistent)

P - 3: After power on, relay 1 pulls up to A time release, waiting for C time, relay 2 pulls to B time release, waits for C time; relay 1,2 turns endless operation endless cycle

(If the control motor is reversible can be understood as: the motor is running a period of time; stop for some time; automatically reverse for some time; stop for some time; then automatically forward;

P - 4: to signal 1, relay 1 pull; to signal 2 (limit), relay 1 stops and starts counting to A time relay 2 pull; to signal 3 (limit), relay 2 stops and starts timing To B time relay 1 pull; infinite loop

(If the control motor is reversible can be understood as: press the start button 1; the motor is moving to the limit 2 to stop for a period of time; automatically reverse to the limit 3 to stop a period of time; then automatically forward;

P - 5: to signal 1, relay 1 pull; to signal 2 (limit), relay 1 stop and start timing to A time relay 2 pull; give signal 3 (limit), relay 2 stop; Signal 1; once again

(If the control motor is reversible can be understood as: press the start button 1; the motor is moving to the limit 2 to stop for a period of time; automatically reverse to the limit 3 stop; give the signal 1;

P-6: to signal 1, relay 1 pull; to signal 2 (limit), relay 1 stop; give signal 1, relay 2 pull; to signal 3 (limit), relay 2 stop;

(If the control motor is reversible can be understood as: press the start button 1; go to the limit 2 stop; press the start button 1 again; reverse to the limit 3 stop;

If the remote control function: remote control A key and B key to start the above function; C key press the relay 1 work (forward); then press the relay 1 to stop (stop); D key press the relay 2 work (reverse); Press once relay 2 to stop (stop);

Whats in the box

  • inc