Feature(may vary by option.)

●【Connection way】Connect the 110V input wire to any 2 terminals in the "R" "S" and "T".The motor wire is connected to the UVW terminal
●【Multiplex terminal】Unlike other inexpensive VFDS, this VFD has two sets of terminal functions,Rich of digital and analogy control terminals for versitile control,optional MODBUS (RS485) extension,diversified parameter setting
●【Safety performance】Take advantage of various protection ways such as Motor short-circuit detection at power-on, output phase loss protection, over-current protection, over-voltage protection, under-voltage protection, overheat protection, overload protection and etc.
●【Good Noise Control】The vfd has the advantages of low noise and low electromagnetic interference, which are achieved by the excellent PMW control technology and component compatibility design. There is enough space for cooling between each component, and the product casing is designed with multiple holes, the above features can make this VFD have a longer service life.
●【Warranty】: 1 Year replace .If there is an error code in the product and you do not know how to operate, please contact the seller

[110v single phase ac input-3.0KW]




[110v single phase ac input-2.2KW]




[Black]





Description

vfdvfd

IMPORTANT NOTE

  • Attention:

  1. This VFD is ONLY applicable to three phase asynchronous motor.
  2. This product does not support the installation of brake resistance (this function needs to be customized)
  3. To protect the VFD, be sure to press the red button "Stop" and turn off the power when you stop using it.
  4. If your motor is heavy load, pls choose a higher horsepower vfd than your motors

Huanyang 110V-1.5kw VFD Specifications

Applicable 110V motor power ≤ 1.5kw(3HP)
Input valtage 110VAC(+/-10%) single phase
output valtage 3 phase 110v
input Frequency 47-63Hz
output frequency 0-400Hz, 0-50Hz/60Hz
Package Including 1x manual,1x VFD
Circuit breaker suggestion 20A
Wire specification suggestion 13AWG

Function introduction

fanfan

Motor ControlMotor Control

drive motordrive motor

DC cooling fan

DC cooling fan low noise, large air volume help vfd heat dissipation, improve product stability

basic parameter for 110V-400hz spindle

For 400hz motor:Set pd005=400,pd004=400,pd003=400,pd072=400,pd144=3000,PD008=110,Then you can start driving the 400hz spindle.

(Note:The VFD is already set to 400Hz by default when it is received,)

basic parameter for 3 phase 50/60Hz motor

  • Drive 50/60hz motor:Set pd005=50/60,pd004=50/60,pd003=50/60,pd072=50/60,PD008=110

Multiple terminalsMultiple terminals

Diverse terminals, more functions for you to choose.

  • Unlike other inexpensive VFDS, this VFD has two sets of terminal functions,Rich of digital and analogy control terminals for versitile control,optional MODBUS (RS485) extension,diversified parameter setting.
  • supports external potentiometer control (connect the "FOR" and "DCM" terminals,than set PD001=1)
  • supports mcah3 function and RS-485 communication (For more information, you can contact the seller, we will send you a video of the basic functions of VFD)

key boardkey board

Key Function

  • UP: Progressively increase data or function codes.
  • DOWN: Progressively decrease data or function codes.
  • SET: Enter menus step-by-step, save setting parameters.
  • PRGM: Exit current(or present) state, switch among each states, mainly used to switch monitoring state, exit to previous menu.
  • FWD/REV: 1, Press momentary button to start,release to stop; 2 Switch the rotation direction
  • SHIFT: Switch monitoring parameters at monitoring state, at secondary menu, move data box to process editing position.
  • Kindly Note: If you want to show RPM in the display,please press SHIFT key

Advanced motherboard featuresAdvanced motherboard features

Advanced motherboard features

  • PID control; advanced calculus PID closed-loop arithmetic, quick responding speed and high suitability
  • Easy PLC function can realize 16 legs of speed and inverter control function
  • RS485 communication port, adopting standard international MODBUS main circuit control
  • With extremely strong anti-jamming capability
  • Low output ratting torque0.5HZ-150%, low speed running ability
  • Carrier adjustable by 16KHZ, completely soundless working environment
  • Broad voltage working area, normal running in 304V-456V
  • Auto voltage regulation (AVR) technique, for ensuring the inverter load capability
  • With perfect error protection and short circuit starting protection capability

Whats in the box

  • electronic components