Feature

●XR02CX-5N0C1,in 32x74x50 mm short format,is a digital controller with off cycle defrost designed for refrigeration applications at normal temperature. It provides a relay output to drive the compressor. It is also provided with 1 NTC probe input and one the digital input. The instrument is fully configurable through special parameters that can be easily programmed through the keyboard or by the HOTKEY.
●Suitable for appliances including:FRIDGES,FREEZERS,HEATING APPLIANCES.230V/50-60Hz
●SAFETY PRECAUTIONS Check the supply voltage is correct before connecting the instrument. Do not expose to water or moisture: use the controller only within the operating limits avoiding sudden temperature changes with high atmospheric humidity to prevent formation of condensation. Warning: disconnect all electrical connections before any kind of maintenance. Fit the probe where it is not accessible by the End User. The instrument must not be opened.
●In case of failure or faulty operation send the instrument back to the distributor or to Dixell S.r.l.(see address) with a detailed description of the fault. Consider the maximum current which can be applied to each relay (see Technical Data). Ensure that the wires for probes, loads and the power supply are separated and far enough from each other, without crossing or intertwining.
●Version:Defrosting Function / Time Control.


Description

XR02CX-5N0C1,in 32x74x50 mm short format,is a digital controller with off cycle defrost designed for refrigeration applications at normal temperature. It provides a relay output to drive the compressor. It is also provided with 1 NTC probe input and one the digital input. The instrument is fully configurable through special parameters that can be easily programmed through the keyboard or by the HOTKEY.

SAFETY PRECAUTIONS

Check the supply voltage is correct before connecting the instrument. Do not expose to water or moisture: use the controller only within the operating limits avoiding sudden temperature changes with high atmospheric humidity to prevent formation of condensation. Warning: disconnect all electrical connections before any kind of maintenance. Fit the probe where it is not accessible by the End User. The instrument must not be opened.
In case of failure or faulty operation send the instrument back to the distributor or to Dixell S.r.l.(see address) with a detailed description of the fault. Consider the maximum current which can be applied to each relay (see Technical Data). Ensure that the wires for probes, loads and the power supply are separated and far enough from each other, without crossing or intertwining.
Version:Defrosting Function / Time Control.

Specification
Producer: DIXELL
Type: 230V:XR02CX-5N0C1
Mounting Measurements: 71mm x 29mm
Built-in Depth: 56mm
Supply: 230V50-60Hz
Voltage Type: AC
Probe Type: NTC (
probes included)
Number of Relay Outputs: 1 Relay
Output 1: NO-20A(8) Input: 1NTC
Kind of Protection: IP54
Version: Defrosting FunctionTime Control
Measuring Range: -40 Degree C up to +110 Degree C
Display: 2.5 Digit

Package Include
1 X Dixell XR02CX Digital Thermostat Controller(
probes included)