Feature

●Extremely Durable - Internal resistance 25°C, varies with specifications and lengths between 1,500 mΩ and 4,500 mΩ. Normal working temperature 700-750°C. Less than voltage 750mV but should be heated at least 700°C and ramped up to voltage. This fireplace thermopile is used to maintain the pilot flame on the 1960s wall heater, not used for newer heaters.
●Usage - Suitable for propane gas appliances like fireplaces, hot water heaters, fryers, and stoves normally installed with pilot burners.
●Safety& Energy Savings - Metal aluminum envelope is designed and tested for exact equipment specifications, so they work more efficiently and can result in energy savings over time.
●Excellent Performance - The Thermopile generator contains multiple thermocouples connected in series to increase the millivoltage output. The power generated is sufficient to operate the millivolt gas control system, independent of any outside power source. used with Q314, Q324, Q327, Q377, Q379, Q382 Pilot Burners.
●3 Pcs Thermopile: 36 inches in length, the gas fireplace heater is made of high-quality aluminum materials, which is high temperature resistant, stable in performance, precision processing and manufacturing, safe and reliable in quality, more efficient in work, longer in service life, and can save energy.


Description

Specifications:
Lengths: 36 inches
Wire Material: glass fiber wrapping line, metal aluminum wrapping Line
Voltage: ≤750mV
Output Power: 750 mA
Resistance: 1500-4500mΩ
Operating Temperature: 700-750 ℃

For Models:
QV32 QV32-A QV32B QV32B-A (Pre Serial # 0021080519)
QV36 QV36-A QV36B-A (Pre Serial # 0021076968)
QV36D QV36D-A QV36DB QV36DB-A QVI25 QVI30 QVI35 QVI-25FB QVI-30FB QV Pier Heat N Glo Gas Stoves: AT-Grand (Also fits the B, C and D models)
AT-Insert AT-Supreme (Also fits the B, C, and D models)
AT-ZC and AT-ZC-B Bay Insert and Bay Insert NS CFX Grand-B CFX-IN-B FB-Grand FB-IN FB-ZC Grand-I35-SP Grand-XT Supreme-I30-SP Supreme-XT ZC-XT Bay-38HV Bayfyre-TRS Bay-GDV-95 - After May 1996 L-COR-TR L-COR-TRC L-COR-IPI Pier-38HV Pier-TR Pier-TRC Pier-TVFL R-COR-TR R-COR-TRC R-COR-TRC-IPI ST-38HV ST-42TVFL ST-TR ST-TRC 6000BE 6000Camp 6000DVTFL - After serial # 12614 6000FLS 6000G 6000GBV 6000GDVFL - After date code 2/96 (Only for 30 sec pilot assembly) 6000SEB 6000TRB 6000TRI 6000TRI-SP 6000TR-NF 6000TR-OAK 6000TRXI 6000TVB 6000TV-OAK 6000XL 6000XLS 6000XLS-NF 6000XLSB 6000XLT 6000XLT-NF 6000XLTB 7000TR-NF 7000TV-NF 7000XLS-NF 7000XLT-NF 8000C & 8000C-LP 8000DVTFL - After date code 2/96 8000GDVFL - After date code 2/96 8000TR 8000TRC 8000TRD 8000TR-Oak - Pre serial # 0021116425 8000TVC 8000TVD 8000TV-Oak - Pre serial # 0021116948 BE-41 BE-41B BE-41B-IPI

Note: Dont overbend the wire of the fireplace thermopile, otherwise it may cause short circuits and other problems; Only heat at 1/3 of the head; It takes about 1-2 minutes to heat to 750mv