●Power Supply: The meter can be powered by included Φ5 DC power supply cable and mini USB cable. You can also install 4×AA batteries. Each way makes the meter work. Note: the AA battery is not included.
●Measuring Range: Capacitance 0.01pF-100mF, inductance 0.001uH-100H, frequency 500KHz/500Hz-50KHz.
●High Precision: Accuracy 1% of capacitance range 1pF~1uF, 5% of range 1uF~100mF; 1% of inductance range 1uH~1H, 5% of range 1H~100H
●Easy to Calibrate: just press the button "ZERO" to calibrate, open circuit calibration in capacitance measuring mode, short circuit calibration in inductance measuring mode.
●Applications: This portable and handheld tester 1×handheld LC meter, 1 pair of alligator clip test leads, 1×LCR Kelvin alligator clip test lead, 1×mini USB cable, 1×manual


Description

LC-200ALC-200A

UCTRONICS handheld LC meter U6228 is based on the LC resonant principle, and it adds precision measurement calculation of high-speed microcontroller, so that the meter has the advantage of wide measuring range and high precision, especially suitable for creating radio frequency filters, traps and other radio related stuff. It is very good when dealing with <10pF or uH where other measurement items fall down.

  • Supply Voltage: 5V
  • Power Supply: Φ5 DC power supply and mini USB cable (both of them included), or 4*AA batteries (not included)
  • Dimensions (L x W x H): 150 x 89 x 29mm
  • Weight: 198g

pf capacitorpf capacitor

FEATURES

Measurement Range:

  • C -----Capacitance (0.01pF-10uF)
  • L -----Inductance (0.001uH-100mH)
  • Hi.L -----Large inductance (0.001mH-100H)
  • Hi.C -----Large capacitance (1uF-100mF)

Calibration:

  • Capacitance mode -----open circuit calibration;
  • Inductance mode -----short circuit calibration.

Frequency display:

  • Press the function button while testing, the current frequency will be displayed.

SPECIFICATIONS

Mode “C”: measure small capacitance

  • Accuracy: 1pF~1uF--1%; 1uF~10uF--5%
  • Resolution: 0.01pF

Mode “L”: measure small inductance

  • Accuracy: 1uH~100mH--1%
  • Resolution: 0.001uH

Mode “Hi.L”: measure large inductance

  • Accuracy: 100mH~1H--1%; 1H~100H--5%
  • Resolution: 0.001mH

Mode “Hi.C”: measure large capacitance

  • Accuracy: 1uF~100mF--5%
  • Resolution: 0.01uF

Test frequency:

  • Mode “C”, mode “L”~500KHz
  • Mode “Hi.L”~500Hz ~50KHz

The measurement method of large capacitance: Charge-discharge

Working temperature: 0℃-40℃

Working humidity≤90%RH (At 40 ℃)

Package includes:

  • 1×handheld LC meter
  • 1 pair of alligator clip test leads
  • 1×LCR Kelvin alligator clip test lead
  • 1×mini USB cable
  • 1×Φ5 DC power supply
  • 1×manual

NOTE:

  • The capacitor under test must have been completely discharged, otherwise, the meter will be damaged.
  • It needs more time to measure a big capacitance (over 10mF, more than 1s; 100mF, about 8s).
  • If the meter needs to switch the testing mode, it should be calibrated to keep measurement accuracy.
  • For measuring the electrolytic capacitors, the selected mode should be “Hi.C”.