[UT276A PLUS-FBM]
[UT278A PLUS-FBM]
UT270 series can quickly and safely measure the grounding system without disconnecting circuit ground lines or the need of auxiliary electrodes.These clampsdouble insulation design makes them durable tools for outdoor work and effective in blocking interference signals from the environment.
Grounding resistance measurement in electricity, telecommunication, meteorology, oilfield, architecture and industrial electric equipment
Earth Ground Resistance (Ω) | 0.010Ω~1200Ω(UT278A+)/500Ω(UT276A+) |
Resistance Resolution | 0.001Ω/0.01Ω/0.1Ω/0.5Ω/1Ω/5Ω/10Ω/10Ω/20Ω/30Ω |
Resistance Accuracy | ±(1%+0.01Ω)/±(1%+0.1Ω)/±(1.5%+0.5Ω)/±(2%+1Ω)/±(5%+5Ω)/±(10%+10Ω)/±(20%+20Ω)/±(25%+30Ω) |
Leakage current (A) | 0.00mA~20.0A |
Leakage current Resolution | 0.01mA/ 0.1mA/1mA/ 0.01A/0.1A |
Leakage current Accuracy | ±(2.5%+1mA)/±(2.5%+5mA)/±(2.5%+10mA)/±(2.5%+0.1A)/±(2.5%+0.3A)/±(2.5%+0.5A) |
UT276A+ resistance range | 0-500Ω |
UT278A+ resistance range | 0-1200Ω Current range(0-20A) |
![]() |
![]() |
|
---|---|---|
Earth Ground Clamp meter UT276A+ | Earth Ground Clamp meter UT278A+ | |
Earth Ground Resistance (Ω) | 0.01~500Ω (±(1%+0.01)~±(10%+10)) | 0.01~1200Ω(±(1%+0.01)~±(25%+30)) |
Leakage current (A) | / | 0mA~20A (±(2.5%+1mA)~±(2.5%+0.5A)) |
Display count | 4 digits LCD display | 4 digits LCD display |
Jaw opening | 32mm | 32mm |
Visual and audible alarm | √ | √ |
Auto power off | √ | √ |
Jamming signal recognition | √ | √ |
Over-range display | √ | √ |
Data storage | 300 | 300 |
Ω+A Display | / | √ |